Huber+Suhner 74_Z-0-0-21 SMA, PC3.5 Torque Wrench

후버수너 토크렌치 74_Z-0-0-21




For Series: SMA / PC 3.5mm
Torque: 1.00Nm
AF(across flats): 8.0 mm / .315 in
OPERATING INSTRUCTION
The handing of a torque spanner with a rocking lever principle influences
mainly the adjusted torque.
Please note the following remark: Hold spanner on lever end (label) and apply
tangential force F.



This results in the adjusted torque.

문의:
Email: jib@doultech.co.kr
Telephone: 070 8855 6641

Sunday, July 8, 2018

HUBER+SUHNER Mini din Connector (4.3-10)

4.3-10 Connectors

4.3-10
HUBER+SUHNER 4.3-10 connectors offer very low PIM performance together with weight and compactness advantages. A key feature of this connector is the separation of the electrical and mechanical plane, which results in a lower coupling torque and the possiblility of offering the connector with screw, hand-screw and quick-lock design, thus simplifying the installation effort and offering for all mechanisms a very high and reliable electrical performance independently from the torque applied.

Features


  • Radial contact
  • Compact size (25.4 mm flange)
  • 40% lower weight than 7/16
  • Multiple coupling options
  • Ease of installation
  • Protection of electrical contact points
  • Excellent PIM and RL independent of torque
  • Space saving
  • Lightweight antennas and radios
  • Flexible installation
  • Lower cost of ownership
  • No performance degradation due to infield damages


Applications


  • For Semi-rigid, Sucoform and Multiflex cables

Friday, February 8, 2013

Huber+Suhner 의 RADOX 155S FLR Cable (Automotive Cable)

Huber+Suhner 의 케이블중에 각종 악조건에서 견디기 위하여 개발된 케이블이 RADOX 케이블입니다.
이중  Automotive Cable 중에 하나인 RADOX 155S FLR Cable을 소개합니다.

아직도 국내에서는 잘 알려지지는 않았습니다만, Huber+Suhner 사가 RF cable이나 Adapter (Connector)류뿐만이 아니라 차량용 케이블도 생산하고 있어요.

그중에 Radox 155S FLR cable은 차량용 Single Core Cable중에 하나입니다.
스펙과 자세한 사항을 한번 볼까요?


RADOX® 155S FLR

Number of conductors

1

Cross section

0.35 6 mm2

Voltage rating

60 / 600 V DC

Temperature range

(55 °C) 40 °C to +150 °C (3000 h)

Min. bending radius

3 x cable dia.
 

 

Composition of cable

1. Conductor

stranded tinned or bare copper

2. Insulation

RADOX® 155S, extruded radiation cross-linked polyolefin,

 

various colours

 


Characteristics and specialities

                  High and low temperature resistance

                  Ozone and weathering resistance

                  Resistant to pressure at high temperature

                  Resistant to motor oils, fuels and hydrolysis

                  Flame retardant

                  High abrasion resistance

                  Easy to strip and process
 


Application
Low voltage cable for use in road vehicle applications, such as motor wiring, fan motor or sensor applications.
Standards

Conductor

General

DIN 72551 part 6

ISO 6722 class D, thin wall

ISO 6722

DIN 72551 part 5 (1993)

DIN EN 13602, Cu-ETP1-A (CW003A)

LV 112
 
Dimensions according to DIN 72551 part 6 type A
Cross section
Conductor
Conductor resistance @ 20 °C max. /km
Core
Weight
mm2
construction* n x mm
diameter . max. mm
tinned
bare
wall thickness min. mm
diameter mm
kg/100 m nom.
0.35
7 x 0.26
0.8
54.5
52.0
0.20
1.25 ± 0.05
0.4
0.5
19 x 0.19
1.0
38.2
37.1
0.22
1.50 ± 0.10
0.6
0.75
19 x 0.23
1.2
25.4
24.7
0.24
1.80 ± 0.10
0.9
1.0
19 x 0.26
1.35
19.1
18.5
0.24
2.00 ± 0.10
1.1
1.5
19 x 0.32
1.7
13.0
12.7
0.24
2.30 ± 0.10
1.6
2.5
19 x 0.41
2.2
7.8
7.6
0.28
2.85 ± 0.15
2.6
 
Dimensions according to DIN 72551 part 6 type B
Cross- section
Conductor
Conductor resistance @ 20 °C max. /km
Core
Weight
mm2
construction* n x mm
diameter . max. mm
tinned
bare
wall thickness min. mm
diameter mm
kg/100 m nom.
0.75
24 x 0.21
1.2
25.4
24.7
0.24
1.80 ± 0.10
0.9
1.0
32 x 0.21
1.35
19.1
18.5
0.24
2.00 ± 0.10
1.1
1.5
30 x 0.26
1.7
13.0
12.7
0.24
2.30 ± 0.10
1.6
2.5
50 x 0.26
2.2
7.8
7.6
0.28
2.85 ± 0.15
2.6
4.0
56 x 0.31
2.75
4.8
4.7
0.32
3.55 ± 0.15
4.2
6.0
84 x 0.31
3.3
3.2
3.1
0.32
4.15 ± 0.15
6.1
 
Dimensions according to ISO 6722
Cross section
Conductor
Conductor resistance @ 20 °C max. /km
Core
Weight
mm2
construction* n x mm
diameter . max. mm
tinned
bare
wall thickness min. mm
diameter mm
kg/100 m nom.
4.0
37 x 0.38
2.75
4.80
4.70
0.32
3.55 ± 0.15
4.2
6.0
37 x 0.46
3.30
3.20
3.10
0.32
4.15 ± 0.15
6.1
 
* typical value x max. single wire diameter