Huber+Suhner 의 케이블중에 각종 악조건에서 견디기 위하여 개발된 케이블이 RADOX 케이블입니다.
이중 Automotive Cable 중에 하나인 RADOX 155S FLR Cable을 소개합니다.
아직도 국내에서는 잘 알려지지는 않았습니다만, Huber+Suhner 사가 RF cable이나 Adapter (Connector)류뿐만이 아니라 차량용 케이블도 생산하고 있어요.
그중에 Radox 155S FLR cable은 차량용 Single Core Cable중에 하나입니다.
스펙과 자세한 사항을 한번 볼까요?
RADOX® 155S FLR
|
Number of conductors
|
1
|
Cross section
|
0.35
– 6 mm2
|
Voltage rating
|
60 /
600 V DC
|
Temperature range
|
(–55 °C) –40 °C to +150 °C (3000 h)
|
Min. bending radius
|
3 x
cable dia.
|
Composition of cable
|
1.
Conductor
|
stranded
tinned or bare copper
|
2.
Insulation
|
RADOX® 155S, extruded radiation cross-linked
polyolefin,
|
|
various
colours
|
Characteristics
and specialities
High and low temperature resistance
Ozone and weathering resistance
Resistant to pressure at high temperature
Resistant to motor oils, fuels and hydrolysis
Flame retardant
High abrasion resistance
Easy to strip and process
Application
Low voltage cable for
use in road vehicle applications, such as motor wiring, fan motor or sensor
applications.
Standards
Conductor
|
General
|
DIN
72551 part 6
|
ISO
6722 class D, thin wall
|
ISO
6722
|
DIN
72551 part 5 (1993)
|
DIN
EN 13602, Cu-ETP1-A (CW003A)
|
LV
112
|
Dimensions according to DIN 72551 part 6 type A
Cross section
|
Conductor
|
Conductor resistance @ 20 °C max. Ω/km
|
Core
|
Weight
|
mm2
|
construction* n x mm
|
diameter . max. mm
|
tinned
|
bare
|
wall thickness min. mm
|
diameter mm
|
kg/100 m nom.
|
0.35
|
7 x 0.26
|
0.8
|
54.5
|
52.0
|
0.20
|
1.25 ± 0.05
|
0.4
|
0.5
|
19 x 0.19
|
1.0
|
38.2
|
37.1
|
0.22
|
1.50 ± 0.10
|
0.6
|
0.75
|
19 x 0.23
|
1.2
|
25.4
|
24.7
|
0.24
|
1.80 ± 0.10
|
0.9
|
1.0
|
19 x 0.26
|
1.35
|
19.1
|
18.5
|
0.24
|
2.00 ± 0.10
|
1.1
|
1.5
|
19 x 0.32
|
1.7
|
13.0
|
12.7
|
0.24
|
2.30 ± 0.10
|
1.6
|
2.5
|
19 x 0.41
|
2.2
|
7.8
|
7.6
|
0.28
|
2.85 ± 0.15
|
2.6
|
Dimensions
according to DIN 72551 part 6 type B
Cross- section
|
Conductor
|
Conductor resistance @ 20 °C max. Ω/km
|
Core
|
Weight
|
mm2
|
construction* n x mm
|
diameter . max. mm
|
tinned
|
bare
|
wall thickness min. mm
|
diameter mm
|
kg/100 m nom.
|
0.75
|
24 x 0.21
|
1.2
|
25.4
|
24.7
|
0.24
|
1.80 ± 0.10
|
0.9
|
1.0
|
32 x 0.21
|
1.35
|
19.1
|
18.5
|
0.24
|
2.00 ± 0.10
|
1.1
|
1.5
|
30 x 0.26
|
1.7
|
13.0
|
12.7
|
0.24
|
2.30 ± 0.10
|
1.6
|
2.5
|
50 x 0.26
|
2.2
|
7.8
|
7.6
|
0.28
|
2.85 ± 0.15
|
2.6
|
4.0
|
56 x 0.31
|
2.75
|
4.8
|
4.7
|
0.32
|
3.55 ± 0.15
|
4.2
|
6.0
|
84 x 0.31
|
3.3
|
3.2
|
3.1
|
0.32
|
4.15 ± 0.15
|
6.1
|
Dimensions
according to ISO 6722
Cross section
|
Conductor
|
Conductor resistance @ 20 °C max. Ω/km
|
Core
|
Weight
|
mm2
|
construction* n x mm
|
diameter . max. mm
|
tinned
|
bare
|
wall thickness min. mm
|
diameter mm
|
kg/100 m nom.
|
4.0
|
37 x 0.38
|
2.75
|
4.80
|
4.70
|
0.32
|
3.55 ± 0.15
|
4.2
|
6.0
|
37 x 0.46
|
3.30
|
3.20
|
3.10
|
0.32
|
4.15 ± 0.15
|
6.1
|
*
typical value x max. single wire diameter